KIPOR WEBSITE:
Product Description
Easier and more convenient electric starter
New AVR(Automatic Voltage Regulator) stablizes the output power
Low oil level alarming system will automatically stop the generator when lube oil is less than the set value
FEATURES
Strong power
All generator sets are equipped with KIPOR four-stroke engines.
Low noise running
High effective combustion system ensures complete combustion, Besides, a large silencer dampens exhaust noise and engine sounds which are contained by a double-wall structure and absorbed by a liner.
Digital control panel
All the control units of the generator sets are on one panel, a monitor of the panel will display the real-time working data of the generator set such as its output voltage and current etc. Besides, the running trouble of the generator will also be displayed on the panel.
Low oil alarm system
Before the oil level drops to the limited level, the generator set will stop automatically. The whole set can be restarted only if the oil is refilled.
Application of new AVR
The AVR (Automatic Voltage Regulator) not only can smooth the output but also can provide reasonable protection against the overload of the whole set, thus avoid damage to the set.
Advanced alternator winding
Waveform distortion is kept at a minimum level and the output is stable. The winding design protects the generator from short circuits and provides a stable output while running inductive loads.
ATS (Automatic Transfer Switch)
On the inheriting of the original general-purpose generator set, KIPOR diesel generator sets with digital control panel can be equipped with a made ATS(automatic transfer switch). ATS, in its preset intervals, can automatically check and monitor the running of the genset to ensure the genset in good working condition. Meanwhile, ATS will monitor the utility power, if utility power fails or the voltage and frequency of the utility power become abnormal, ATS will give commands to start the genset automatically.
Model
KDE6700T
Rated frequency (Hz)
50 60
Rated output (kVA)
4.5 5.0
Max. output (kVA)
5.0 5.5
Rated Voltage (V)
115/230 120/240
Rated current (A)
39.2/19.6 41.7/20.8
Rated rotation speed (r/min)
3000 3600
Phase NO.
Single phase
Power factor (Cos Φ)
1.0
Insulation Grade
B
Pole number
2
Excitation mode
Self-excitation & constant voltage (AVR)
Panel Type
General Panel
Voltage (V)
115/230 120/240
Receptacle
Two receptacles
Connection pole
Without
DC12V output
Connection pole output
Overall dimension(L×W×H)(mm)
930X535X742
Dry weight(kg)
170
Working assorting weight (Kg)
185
Noise level(7m)dB(A)
72
Structure type
Silent
Engine Model
KM186FAGET
Engine Type
Single cylinder, vertical, four-stroke, direct injection
Cylinder NO.-bore×stroke (mm)
1-86×72
Make | Lincoln |
You must Register or Login to post a comment